Questions and Answers

  • A
    Angelica GonzalezAug 2, 2025
    How to access the onboard configuration program of Edge-Core Switch via a serial port connection?
    • C
      contreraslauraAug 2, 2025
      To access the onboard configuration program via a serial port connection, ensure your terminal emulator program is set to VT100 compatible, with 8 data bits, 1 stop bit, no parity, and the baud rate set to 9600, 19200, 38400, 57600, or 115200 bps. Also, check that the null-modem serial cable conforms to the pinout connections specified in the Installation Guide.
  • J
    jthompsonAug 21, 2025
    What to do if I cannot connect to my Edge-Core Switch using Secure Shell?
    • L
      Lauren GarzaAug 21, 2025
      If you're having trouble connecting to your Edge-Core Switch via Secure Shell, first ensure that the SSH server's control parameters are correctly configured on the switch and that the SSH client software is properly configured on your management station. Also, confirm that you have generated both an RSA and DSA public key on the switch, exported this key to the SSH client, and enabled the SSH service. Verify that you've set up an account on the switch for each SSH user, including a username, authentication level, and password. If using public key authentication, ensure you've imported the client's public key to the switch.
  • J
    Jordan GarciaNov 10, 2025
    Why can't I connect to my Edge-Core Switch using Telnet, a web browser, or SNMP software?
    • K
      Kara CoxNov 10, 2025
      There could be several reasons why you are unable to connect to your Edge-Core Switch. First, ensure the switch is powered on and that the network cabling between your management station and the switch is correctly connected. Also, verify that you have a valid network connection to the switch and the port you're using hasn't been disabled. Confirm that the VLAN interface, through which the management station connects, is configured with a valid IP address, subnet mask, and default gateway. Make sure the management station's IP address is in the same subnet as the switch’s IP interface. If connecting via a tagged VLAN group's IP address, your management station and the intermediate switches' ports must have the correct tag. If using Telnet or SSH, you might have exceeded the maximum number ...

Edge-Core ES3510MA-DC Specifications

General IconGeneral
Switch TypeManaged
Power SupplyDC
LayerLayer 2
MAC Address Table8K
Switching Capacity20 Gbps
Forwarding Rate14.88 Mpps
Power Input48V DC
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Uplink Ports2 x 100/1000Base-X SFP
Jumbo Frame Support9K bytes
Humidity10% to 90% (non-condensing)