EasyManuals Logo

Edge-Core ES3510MA-DC User Manual

Edge-Core ES3510MA-DC
1098 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #935 background imageLoading...
Page #935 background image
C
HAPTER
39
| LLDP Commands
– 935 –
lldp This command enables LLDP globally on the switch. Use the no form to
disable LLDP.
SYNTAX
[no] lldp
DEFAULT SETTING
Enabled
COMMAND MODE
Global Configuration
EXAMPLE
Console(config)#lldp
Console(config)#
lldp holdtime-
multiplier
This command configures the time-to-live (TTL) value sent in LLDP
advertisements. Use the no form to restore the default setting.
SYNTAX
lldp holdtime-multiplier value
no lldp holdtime-multiplier
value - Calculates the TTL in seconds based on
(holdtime-multiplier * refresh-interval) ≤
65536
(Range: 2 - 10)
DEFAULT SETTING
Holdtime multiplier: 4
TTL: 4*30 = 120 seconds
COMMAND MODE
Global Configuration
COMMAND USAGE
The time-to-live tells the receiving LLDP agent how long to retain all
information pertaining to the sending LLDP agent if it does not transmit
updates in a timely manner.
EXAMPLE
Console(config)#lldp holdtime-multiplier 10
Console(config)#