| CFM Commands
– 963 –
messages are sent (page 980), or setting the start-up delay for the cross-
check operation (page 986). You can also enable SNMP traps for events
discovered by continuity check messages (page 982) or cross-check
messages (page 986).
ethernet cfm ais
level
This command configures the maintenance level at which Alarm Indication
Signal (AIS) information will be sent within the specified MA. Use the no
form restore the default setting.
SYNTAX
ethernet cfm ais level level-id md domain-name ma ma-name
no ethernet cfm ais level md domain-name ma ma-name
level-id – Maintenance level at which AIS information will be sent.
(Range: 0-7)
domain-name – Domain name. (Range: 1-43 alphanumeric
characters)
ma-name – Maintenance association name. (Range: 1-45
alphanumeric characters)
DEFAULT SETTING
Level 0
COMMAND MODE
Global Configuration
COMMAND USAGE
The configured AIS level must be higher than the maintenance level of the
domain containing the specified MA.
EXAMPLE
This example sets the maintenance level for sending AIS messages within
the specified MA.
Console(config)#ethernet cfm ais level 4 md voip ma rd
Console(config)#