The reply will be as follows:
Reply = S
8 5 6
sp
d d d
cr
Timer seng and opons
The meout period is a user-congurable opon and can be set to any value from 1 to
30 minutes.
When the pump is shipped, it is
congured with a default meout period of 8 minutes.
Refer to Timer on page 14 for a full descripon of mer funconality.
To change the mer seng, send the following command (where the characters 'd' represent
the meout period in minutes):
Command
! S
8 5 4
sp
d d
cr
The reply will be in the following format:
Reply
* S
8 5 4
sp
r
cr
The mer seng is now stored in memory within the nEXT85 pump.
To check what meout period is set, send a query as follows:
Command
? S
8 5 4
cr
The reply will be as follows:
Reply
= S
8 5 4
sp
d d
cr
The mer is permanently enabled during ramp-up, however it is oponal to have it enabled at
other mes. When the pump is shipped, the mer is enabled by default.
To disable the mer, send the following serial command:
Command
! S
8 7 0
sp
0
cr
The reply will be in the following format:
Reply
* S
8 7 0
sp
r
cr
The state of the mer opon is stored in memory within the nEXT85 pump.
To enable the mer again, send the following serial command:
Command
! S
8 7 0
sp
1
cr
The reply will be as follows:
Reply
* S
8 7 0
sp
r
cr
To check whether the mer is enabled or disabled, send the following query:
Command
? S
8 7 0
cr
B8G0-00-880A - Conguraon