Bit number Status ag Acve ags mean
3 Vent valve closed Vent valve energised / de-energised
according to the valve type opon
4 Start Start command acve
5 Serial enable Serial command acve
6 Standby Standby acve
7 Half full speed Above 50% full rotaonal speed
8 Parallel control mode Exclusive control mode selecon
9 Serial control mode Exclusive control mode selecon
10 Invalid Controller soware Controller internal soware mismatch
11 Controller upload incomplete Controller failed internal conguraon
and calibraon operaon
12 Timer expired Failure to reach or maintain half full
speed within the mer seng value
13 Hardware trip Overspeed or overcurrent trip acvated
14 Thermistor error Pump internal temperature
measurement system disconnected or
damaged
15 Serial control mode interlock Serial enable has become inacve
following a serial Start command
The system status word used in the example above was obtained with the pump at rest. By
decoding the word, we can learn more about the state of the pump.
Table 17
Example decoding of system status words
Bit number Status of bit
(in example)
We can deduce
0 0 The pump has not failed
1 1 The pump is at rest
2 0 Speed is below normal speed
3 0 The vent valve is open
4 0 There is no acve start command
5 1 Serial enable is acve
6 0 Standby is not acve
7 0 Speed is below 50% of full rotaonal speed
8 0 The pump is not in parallel control mode
9 0 The pump is not in serial control mode
10 0 There is no controller internal soware mismatch
11 0 Controller passed internal conguraon and calibraon
operaon
12 0 The mer has not med out
B8G0-00-880A - Troubleshoong