Cause A service is required.
Remedy See Flashing service codes on page 69.
The red alarm LED is on
Cause Normal during the soware upgrade process. At other mes indicates a problem has been
detected in the FLASH memory.
Remedy If during soware upgrade then complete the upgrade process. Otherwise cycle power and if
this does not help then perform a soware upgrade.
The red alarm LED is ashing
Cause A fail condion has become acve.
Remedy Note the posion of the long ashes within the series of 6 ashes to work out the error code.
Look up the ashing error code in Flashing error codes on page 69 and follow the advice
given.
Any other problems
Cause Fault condions other than the ones previously menoned.
Remedy Contact the supplier or Edwards.
Command set error codes
Error codes that may be returned for serial control and monitoring.
Table 12
Command set error codes
Returned error code Meaning
0 No error
1 Invalid command for object ID
2 Invalid Query/Command
3 Missing parameter
4 Parameter out of range
5 Invalid command in current state - e.g. serial command
to start/stop when in parallel control mode
B8G0-00-880A - Troubleshoong
Page 68