Flashing service codes
Whenever a service is required the standard once per revoluon ash on the yellow status LED
is replaced with a service ash code.
Table 13
Flashing service codes
Service ash code Comments Acons
LED on 1 sec
LED o 1 sec
Oil cartridge service
recommended
It is recommended that the oil
cartridge is replaced. Refer to
Bearing and oil cartridge on-
site maintenance.
LED on 3 sec
LED o 1 sec
Bearing and oil cartridge
service recommended
It is recommended that the
bearing and oil cartridge are
replaced. Refer to Bearing and
oil cartridge on-site
maintenance.
LED on 3 sec
LED o 3 sec
Pump service required The turbo rotor or controller
has reached its expected life.
It is recommended that the
pump is returned to an
Edwards service centre for
service. Refer to Service.
Flashing error codes
Whenever a fail
condion becomes acve, the red alarm lights connuously or shows a
ashing sequence.
If the error light is on
connuously, this indicates a problem with the embedded soware. In
this case, try cycling the power. If cycling the power does not clear the indicaon, a soware
download will be required. Contact the supplier or Edwards. If the alarm LED is ashing,
idenfy the error ash code and consult the table in Decoding system status words on page
70.
There is a sucient o period between each subsequent cycle repeon to clearly mark the
start of a new ash sequence. The duraon of a long ash (L) is equal to 3 mes the duraon
of a short ash (0.5 s).
Table 14
Flashing error codes
Error ash
posion
Error ash
code
Comments Acons
0 ssssss The speed fell below 50% of
full rotaonal speed with the
mer disabled.
Check whether the pump is
too hot or whether the inlet
pressure is too high.
1 Lsssss Controller internal soware
mismatch.
Cycle the power to the pump
and see whether the error
code appears again. If it does,
contact the supplier or
Edwards.
B8G0-00-880A - Troubleshoong
Page 69

Table of Contents

Other manuals for Edwards nEXT85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards nEXT85 and is the answer not in the manual?

Edwards nEXT85 Specifications

General IconGeneral
BrandEdwards
ModelnEXT85
CategoryWater Pump
LanguageEnglish

Related product manuals