EasyManuals Logo

Edwards nEXT85 User Manual

Edwards nEXT85
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
Bit number Status of bit
(in example)
We can deduce
13 0 Overspeed and overcurrent trip not acvated
14 0 Pump internal temperature measurement system is ne
15 0 Serial enable has not become inacve during serial control
Service informaon
When using the serial communicaons link, addional informaon about the pump, such as
pump type and internal controller soware versions, can be accessed. This informaon is
parcularly useful for service personnel to determine the model of the pump.
Send the following query to nd out pump type:
Command
? S
8 5 1
cr
The reply will be as follows, where string 1 is the pump type, string 2 is the DSP soware
version number and string 3 is the designated full speed of the pump (in revoluons per
second):
Reply
= S
8 5 1
sp
String
1
;
String
2
;
String
3
cr
Send the following query to nd out the boot loader soware version:
Command
? S
8 6 8
cr
The reply will be as follows, where string1 is the boot loader soware version number:
Reply
= S
8 6 8
sp
String
1
cr
B8G0-00-880A - Troubleshoong
Page 73

Table of Contents

Other manuals for Edwards nEXT85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards nEXT85 and is the answer not in the manual?

Edwards nEXT85 Specifications

General IconGeneral
BrandEdwards
ModelnEXT85
CategoryWater Pump
LanguageEnglish

Related product manuals