122
SMS
N/A
EKB2
Menu path:
OK → CONFIGURATION → ARC SET → COMMUNICATION → ATTEMPTS PERIOD → [XXXXX]
Value: [XXXXX] – delay between attempts time period in seconds, range – [0...
65535]
EKB3
Enter parameter 69 & time period:
[69x#]
Value: x - delay between attempts time period in seconds, range – [0... 65535]
This feature allows to set a delay period of time between data message sending at tempts to
monitoring station in case the initial attempt was unsuccessful. By default, this time period
is 600 seconds.
Delay Between
Attempts
SMS
N/A
EKB2
Menu path:
OK → CONFIGURATION → ARC SET → COMMUNICATION → TEST PERIOD → [XXXXX]
Value: [XXXXX] – test time period in seconds, range - [1... 65535]
EKB3
Enter parameter 46 & test time period:
[46xx#]
Value: xx – test time period in seconds, range - [1... 65535]
Time period of data test message sending to monitoring station. This message is inten ded for
alarm system status checking. The default test period is 180 seconds.
Test Period