Adjustment Adjustment 139
5.2.2 PG Adjustment
When any of the following parts has been removed or replaced, this adjustment
must be performed to secure the specified clearance between the print surface
of the Print Head and paper.
Print Head
Carriage Unit
Carriage Shaft
Parallelism Adjust Bushing (Including the case when just moved it)
In this adjustment, use the same Adjustment Gauge on the left and right sides.
Figure 5-3. Adjustment Gauge
5.2.2.1 PG Adjustment Method
1. Install the printer on a level base.
2. Connect the Tester to the printer frame and Adjustment Gauge.
Figure 5-4. Connecting the Tester
C A U T I O N
Do not touch the Adjustment Gauge Plate surface with
bare hands.
If the Adjustment Gauge Plate surface is stained by ink
or, etc wipe it with a soft cloth.
Continuty
Measuring Point
Adjustment Gauge
Plate (Top face)
C A U T I O N
Before starting PG adjustment, completely wipe drops of
ink around the Print Head. Remaining drops of ink will
stick to the continuity measurement portion of the
Adjustment Gauge, and generate continuity before the
continuity measurement portion makes contact with the
metal frame around the Print Head, interrupting accurate
PG Adjustment.
As the ink in the Print Head may stick fast and damage
the Print Head during PG Adjustment, make the
continuity time detected with a tester as short as
possible. (Maximum 3 minutes)
C A U T I O N
Place the printer on a level, warp-free table. Normal PG
Adjustment cannot be performed on a warped table.
Tester
Adjustment Gauge
Frame