EPSON Stylus Photo R1800/R2400 Revision B
Disassembly And Assembly Disassembly 95
4.2.6.4 Carriage Shaft and Carriage Unit
1. Remove the LED Board. See Section 4.2.5.2 on page 89.
2. Remove the Print Head. See Section 4.2.6.1 on page 89.
3. Remove the CR Scale. See Section 4.2.6.2 on page 91.
4. Remove the APG Assy. See Section 4.2.6.3 on page 93.
5. Point any position other than PG++ on the PG Cam (Right) to face down.
Figure 4-49. Setting the PG Cam
6. Remove the two C.B.S. M3 x 6 screws that secure the Frame Support
Plate (Left), and remove it.
Figure 4-50. Removing the Left Frame Support Plate
PG Cam (Right)
Insert the Left Frame Support Plate into the notch on the
Main Frame. See Figure 4-50.
Align the two Tabs on the Main Frame and the Tab on the
Paper EJ Frame Assy with the three positioning holes on
the Frame Support Plate (Left). See Figure 4-50.
Align the Tab (rear side) of the Left Frame Support Plate
with the outside of the Left CR Shaft Mounting Plate. See
Figure 4-50.
Tighten the screws in the order shown in Figure 4-50.
1
2
2) C.B.S. 3x6
(8±1 kgf.cm)
Tab
Tabs
Left Frame Support Plate
Paper EJ Frame Assy.
Notch