EPSON Stylus Photo R1800/R2400 Revision B
Disassembly And Assembly Disassembly 93
4.2.6.3 APG Assy
1. Remove the Upper Housing. See Section 4.2.1.4 on page 76.
2. Disconnect the APG Motor Connector Cable from Connector CN18 (red)
on the Main Board, and Remove the Cable from the ASF Assy.
3. Disconnect the Connector Cables from the two APG Sensor Connectors.
Figure 4-45. Disconnecting the Connector Cables
Pass the CR Scale through the slot on the CR Encoder.
Figure 4-42. Reinstalling the CR Scale (1)
Set the left end of the CR Scale with the chamfered edge
facing upwards.
Figure 4-43. Reinstalling the CR Scale (2)
Place the right end of the CR Scale correctly so that it is
not hooked onto the Right CR Shaft Mounting Plate.
Figure 4-44. Reinstalling the CR Scale (3)
CR Encoder
CR Scale
CR Scale
Chamfered edge
CR Scale
Hooked Portion
OK
NG
Referring to Figure 4-45., correctly route the APG Connector
Cable.
APG Assy
APG Sensor Connectors
CN18
APG Motor