4. Commissioning positioning systems
4−46
Festo P.BE−SPC200−WIN−PISA−CD−EN en 0901d
7. You can modify the valve voltage with the buttons under
Valve voltage". If you modify the direction of movement
with the buttons, the valve voltage will immediately be set
to 5V.
Button
Function
Reduce < < or
< <
Reduces the valve voltage continuously
< or
<
Reduces the valve voltage by 0.02 V
Increase > or
<
Increases the valve voltage by 0.02 V
> > or
< <
Increases the valve voltage continuously
In order to overcome the static friction, the control voltage
must be increased or reduced accordingly.
8. Reduce the valve voltage with the buttons near Reduce"
until the axis starts to move. Check the direction of move
ment of the axis. To do this you can refer to the display
under Axis movement". Then
set the valve voltage to 5V
with one of the buttons near Increase" and stop the axis.
9. Increase the valve voltage with the buttons near In
crease" until the axis starts to move. Check the direction
of movement of the axis. To do this you can refer to the
display under Axis movement".
Then set the valve vol
tage to 5V with one of the buttons near Reduce" and
stop the axis.