Contents and general instructions
XXXIV
Festo P.BE−SPC200−WIN−PISA−CD−EN en 0901d
N000 G01 X50 FX50 ;Adapt pos. 50
N001 G01 X200 FX50 ;Adapt position 200
N002 M30 ;Program end
3. Carry out a syntax check if required (command [Compile]
[Syntax check]).
4. Load the program into the SPC200 (command [Online]
[Download] [Programs], select the program, confirm with
OK").
Step 9
Setting the operating mode and start programs
(see also section 4.10)
1. If necessary, activate the online mode (command [Online]
[Online mode]).
2. Mark the icon SPC200−.." in the project window and open
the dialogue window SPC200 configuration" (command
[Edit] [Configure]).
3. Set the operating mode and the start programs in the tab
card Operating mode/Start programs".
Recommendation
(for first commissioning):
· Determine the test program entered as start program A.
Deactivate start program B (Startpr. B=***).
· Set the operating mode Start/Stop. Programs can then be
controlled independently of a higher−order PLC/IPC e.g.
with the control panel (easier test possibilities).
4. Load the settings into the SPC200 with Download".
5. Accept the settings with OK". Save any modifications to
the project (with active project window, command [File]
[Save]).