Contents and general instructions
XXXIV
Festo P.BE−SPC200−WIN−PISA−CD−EN en 0901d
N000 G01 X50 FX50 ;Adapt pos. 50
N001 G01 X200 FX50 ;Adapt position 200
N002 M30 ;Program end
3. Carry out a syntax check if required (command [Compile]
[Syntax check]).
4. Load the program into the SPC200 (command [Online]
[Download] [Programs], select the program, confirm with
OK").
Step 9
Setting the operating mode and start programs
(see also section 4.10)
1. If necessary, activate the online mode (command [Online]
[Online mode]).
2. Mark the icon SPC200−.." in the project window and open
the dialogue window SPC200 configuration" (command
[Edit] [Configure]).
3. Set the operating mode and the start programs in the tab
card Operating mode/Start programs".
Recommendation
(for first commissioning):
· Determine the test program entered as start program A.
Deactivate start program B (Startpr. B=***).
· Set the operating mode Start/Stop. Programs can then be
controlled independently of a higher−order PLC/IPC e.g.
with the control panel (easier test possibilities).
4. Load the settings into the SPC200 with Download".
5. Accept the settings with OK". Save any modifications to
the project (with active project window, command [File]
[Save]).