Franke Kaffeemaschinen AG
TD-100356.doc 16 / 32
The factory settings of the Flair can now be updated with the generated factory parameters
card.
Switch on the terminal using the “ON/OFF” button.
Enter date
D:02 M:02 Y:2005
Confirm each entry of the date with the ENTER key or enter a new date with the numerical
keypad.
Enter time
H:14 M:25 S:24
Confirm each entry of the time with the ENTER key or enter a new time with the numerical
keypad.
Terminal ready
Data loaded
Insert the “Factory parameters” chip card into the Terminal 3000 chip card reader.
Load the data into the terminal using the “Read card” key.
Please wait
Card à Terminal
Terminal ready
Data is loaded
Select the “Write coffee” key to update the data in the Flair.
Please wait
Terminal à Card
Terminal ready
Data loaded
The Flair has been updated with the factory parameters on the chip card.
Perform this procedure once with the 654 DI and once with the 654 MA chip card!
If the software versions of the machine and the chip cards are different, the error message
“Wrong software version” appears on the terminal.