ADC will be used in normal mode; a conversion will be made on a user request. As the system
clock is 64MHz, we will set ADC to the maximum possible clock, 32MHz, with the minimum
timing parameters given in the documentation. Only channel 0 connected to a potentiometer is
configured, in normal, one-shot mode.