55
EN
Main current (I
1
)
Main current, 2-step mode and spot welding Main current, 4-step mode
Setting range: 3 - 190 ... MW 190 A, 3 - 230 ... MW / TT 230 A
Factory setting: -
IMPORTANT! On welding torches with the Up/Down function, the entire setting range can
be selected while the device is idling.
Reduced current (I
2
)
only in 4-step mode
Reduced current I
2
< Main current I
1
Reduced current I
2
> Main current I
1
Setting range: 0 - 200% (of main current I
1
)
Factory setting: 50%
I
2
< 100%
short-term, adapted reduction of the welding current
(e.g. when changing the welding wire during the welding process)
I
2
> 100%
short-term, adjusted increase in welding current
(e.g. to weld over tacked spots at higher power)
The values for Slope1 and Slope2 can be set using the TIG menu.
50 A
+
-
50 A
+
-
+
-
50%
xxA
+
-
150%
xxA
Slope1 Slope2
I
I < 100 %
I > 100 %
Slope1
Slope2