Chapter 9 Page no. 840
ERR-SUB-A-001.fm
GE Healthcare Senographe DS
Revision 1 Service Information and Procedures Class A 2385072-16-8EN
ERR SUB A001 - Generator Error Messages
071/082 E08 Power supply
failure
Generator: timeout on signal
Alim_Puis_OK (Inv_Supply_OK) (going
’low’ or ’high’)
Refer to Job Card TSG A020 - Gener-
ator Power-Up Sequence Flow Charts
on page 1069
071/083 Generator: error reading ’kV law table’
in 0 pt technique (AOP)
072/001 Exposure software error: ACQ_NTR or
ACQ_OVR received at start of first trig-
ger
072/003 Exposure software error: ACQ_NTR or
ACQ_OVR received at end of first trig-
ger
072/004 Exposure software error: unknown ori-
gin of aborted exposure
072/005 Exposure software error: aborted by PM
in 2 pt technique
072/006 Exposure software error: unknown
exposure technique
072/007 E06 Software Error
(gen. CPU)
One system task (at least) not stable
after a delay of 7 s when a Prep is per-
formed. A Senographe component
(tube, rotor, etc.) or IDC is not ready for
the exposure (prepStatusOk message
not sent to Senographe by IDC).
This error is either caused by IDC or
Senographe. When a Senographe
sub-system is not ready, there should
be a second error message displayed
relating to the sub-system causing the
error
072/008 Exposure software error: unknown task
status
072/009 Exposure software error: 0 pt or 1 pt
exposure and Gantry absent
073/001 Gene software error (IST, standby):
parameter display problem
073/002 Gene software error (IST, standby):
unknown tube type
073/003 Gene software error (IST, standby):
alpha=0.0 when calculating value
P_NDac_HTPM
073/004 Gene software error (IST, standby):
incorrect thickness for correlation calcu-
lation
073/005 Gene software error (IST, standby):
bias calibration task problem
073/006 Gene software error (IST, standby):
heater scale calibration task problem
073/007 Gene software error (IST, standby): HV/
DAC calibration task problem
073/008 Gene software error (IST, standby):
FREQ/HV calibration task problem
Code Message text Description Recommended actions

Table of Contents

Other manuals for GE Senographe DS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Senographe DS and is the answer not in the manual?

GE Senographe DS Specifications

General IconGeneral
BrandGE
ModelSenographe DS
CategoryMedical Equipment
LanguageEnglish

Related product manuals