gefran TPD32-EV-...-4B - Figure 5.3.7.2: Blocks Diagrams of Field Current Regulator

gefran TPD32-EV-...-4B
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
—————— Instruction manual ——————
133
+
S
+ T
Field current Limits
Flux current max
Flux current min
Spd=0 Thr
Voltage reg P /IBase
Field reg P /IBase
Field controller
Field reg P/I
I field curve
Voltage regulator
T
M
C1
D1
Output Voltage
Flux
current
min
Flux
current
max
Energy saving
Field economy
Fld reg P gain
2%
Fld reg I gain
1%
Flux current %
Nom flux curr
10 A
Motor field curr
10 A
Ifield cnst40
40 %
Ifield cnst90
90 %
Ifield cnst70
70 %
Voltage P
30 %
Voltage I
40 %
Output voltage
Max. out voltage
500 V
Out vlt level
100 %
Flux current max
100 %
Flux current min
70 %
Enable flux weak
Disabled
Speed-0fweak
Enabled
Motor field curr
10 A
Flux reg mode
Speed zero level
10 rpm
Set flux/if
0
Reset flux/if
0
Flux P base
3277
Flux I Base
3277
Voltage P base
1.8 A/V
Voltage I base
13.0909 A/V*ms
Enable flux reg
Flux reference
S
-
-
Figure 5.3.7.2: Blocks diagrams of field current regulator
Tuning procedure:
- Resetthecurveux/currentviatheReset ux/ifcommand(FLUXREGULATION\Flux/ifcurvemenu)
- SettheMotornomux
: Motor nom ux parameter(FLUXREGULATIONmenu)
- SettheoutputvoltageviatheMax out voltageparameter(CONFIGURATIONmenu)andthecorrespondent
percentage(100%)intheOut vlt levelparameter(FLUXREGULATIONmenu)
- SettheFluxregulatorFlux reg mode=Constantcurrent(FLUXREGULATIONmenu)
- Settheuxpercentageat100%viatheFlux current maxparameter(FLUXREGULATIONmenu)
- OperatetheDrivespeed,sothattheArmature voltage(MONITOR\Measurementsmenu)correspondsto
thevaluepreviouslysetinMax out voltage (CONFIGURATIONmenu).
- ViatheFlux current maxparameterdecreasethevoltagedisplayedinArmature voltage,uptoobtainan
outputvoltageequaltothe90%ofMax out voltage.
CarryoutthereadingofthecurrentintheFlux currentparameter(FLUXREGULATIONmenu)andinsert
itintheI eld cnst 90parameter(FLUXREGULATION\Fluxifcurvemenu).
- ViatheFlux current maxparametersdecreasethevoltagedisplayedinArmature voltage,toobtainan
outputvoltageequaltothe70%ofMax out voltage.
CarryoutthereadingofthecurrentcirculatingintheFlux currentparameter(FLUXREGULATIONmenu)
andinsertitintheI eld cnst 70parameter(FLUXREGULATION\Fluxifcurvemenu).
- ViatheFlux current maxparametersdecreasethevoltagedisplayedinArmature voltage,toobtainan
outputvoltageequaltothe40%ofMax out voltage.
CarryoutthereadingofthecurrentcirculatingintheFlux currentparameter(FLUXREGULATIONmenu)
andinsertitintheI eld cnst 40parameter(FLUXREGULATION\Fluxifcurvemenu).
- Disabletheconverter