EasyManua.ls Logo

gefran TPD32-EV-...-4B - Figure 6.17.4: Functioning with Jog TW Enable

gefran TPD32-EV-...-4B
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
—————— Instruction manual ——————
335
Status 6:
ThesystemreachesthisstatuswhentheparameterJog TW enableisenabledandtheStartcommandhas
beengiven.TheJogcommandisusedonunwindersinordertobringthecoilmaterialtilltherstniproll.
Seegure6.17.4.
Status 1
(default)
Status 6
Jog TWenable=1
Start (drive)=1
Jog TWenable=1
Start (drive)=0
Int acc time=Spd match acc
Int dec time=Spd match dec
W reference=f(Jog TWspeed, )
Int acc time=Spd match acc
Int dec time=Spd match dec
W reference=0
Figure 6.17.4: Functioning with Jog TW enable
Jog TW enablepreparesthesystemforaparticularfunctioningcondition;inordertoenablethecoilrotation
itisnecessarytogivetheStartcommand,afollowingStopwillforcethespeedreferenceto0(seeparagraph
Control logic).
IntheStatus6themotorspeedreferenceissetto:
W reference = Jog TW speed x Minimum diameter ÷ Roll diameter
ItispossibletochangetheJogspeedsignbyusingthecommandWinder side.
IfstartingfromtheStatus6,Jog TW enableisdisabledbykeepingtheStartcommand,thesystemswitches
totheStatus2.