EasyManua.ls Logo

gefran TPD32-EV-...-4B - Signal Adaptation

gefran TPD32-EV-...-4B
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
—————— Instruction manual ——————
277
6.15.4 Signal adaptation
SPEC FUNCTIONS
Links
Link 1
[484] Source
[485] Destination
[486] Mulgain
[487] Divgain
[488] Inputmax
[489] Inputmin
[490] Inputoffset
[491] Outputoffset
[492] Inpabsolute
Link 2 ... 6
[553] [1218] [1227] [1236] [1245] Source
[554] [1219] [1228] [1237] [1246] Destination
[555] [1220] [1229] [1238] [1247] Mulgain
[556] [1221] [1230] [1239] [1248] Divgain
[557] [1222] [1231] [1240] [1249] Inputmax
[558] [1223] [1232] [1241] [1250] Inputmin
[559] [1224] [1233] [1242] [1251] Inputoffset
[560] [1225] [1234] [1243] [1252] Outputoffset
[561] [1226] [1235] [1244] [1253] Inpabsolute
Parameter description
Link 1
No.
Link 2
No.
Link 3
No.
Link 4
No.
Link 5
No.
Link 6
No.
Value
Standard
Conguration
min max
Factory
American
Factory
Standard
Source
484 553 1218 1227 1236 1245 0 65535 0 0 -
Destination
485 554 1219 1228 1237 1246 0 65535 0 0 -
Mul gain
486 555 1220 1229 1238 1247 -10000 +10000 1 1 -
Div gain
487 556 1221 1230 1239 1248 -10000 +10000 1 1 -
Input max
488 557 1222 1231 1240 1249 -231 231-1 0 0 -
Input min
489 558 1223 1232 1241 1250 -231 231-1 0 0 -
Input offset
490 559 1224 1233 1242 1251 -231 231-1 0 0 -
Output offset
491 560 1225 1234 1243 1252 -231 231-1 0 0 -
Inp absolute
OFF/ON
492 561 1226 1235 1244 1253 0 1 OFF OFF -
TheLink1andLink6functionsaretwocontrolsectionoperatingindependentlyofeachotherforthesignal
adaptation.WiththeLinks,parameterscanbe:rectied,limited,multipliedbyafactor,dividedbyafactor
andprovidedwithanoffset.
Source Parameternumberusedasaninputquantity.Forexample“8236”fortheRamp ref 1
parameter(44+8192offset).Selecttheparameternumberintheindividualdescriptions
orinthelistofallparametersinsection10,“Parameterlist”.
Destination Parameternumber,whichdeterminestheoutputquantity.Selecttheparameternumber
(+8192offset)intheindividualdescriptioncolumnorinthelistofallparametersin
section10,“Parameterlists”.
Mul gain Multiplicativefactoroftheinputquantity(afterapossiblelimitation).Resolution:5digits.
Div gain Divisor,throughwhichitispossibletodividetheinputquantityalreadymultipliedand
limited.Resolution:5digits.
Input max Max.limitoftheinputquantity.Resolution:5digits.
Input min Min.limitoftheinputquantity.Resolution:5digits.
Input offset Offsettobeaddedtotheinputquantity.Resolution:5digits.
Output offset Offsettobeaddedtotheoutputquantity.Resolution:5digits.

Table of Contents