—————— TPD32-EV ——————
322
Diam preset sel 1 MSDdigitalinput;preselectionofthestartingdiameter.
Diam reset Resetofthecalculateddiameter.
Taper Enable EnablingoftheTaperfunction.
Speed match Coil“launching”phasecommandforautomaticswitching.
Line acc status Activeacceleration.
Line dec status Activedeceleration.
Line fstp status Fastdeceleration.
Thelastthreeparametersareinputssendingtothedrivethestatusofthelinespeed:they
areusedwhentheinternalcalculationprocedureforthelineaccelerationisdisabled.
Speed demand En Enablingofthespeedreferencecalculation.
Closed loop En Enablingoftheclosedloopcontrol.
Digital outputs
Diameter reached Indication:thediameterthresholdhasbeenovercome.
Spd match compl Indication:the“launching”speedhasbeenreached.
6.17.1 Diameter calculation
OPTIONS
Torque winder
Diam Calculatio
[1154] Rolldiameter[m]
[1160] Linespeed[%]
[1286] Reflinespeed[%]
[1161] DiamcalcDis
[1205] Diaminc/decEn
[1187] Wind/unwind
[799]
Minimumdiameter[mm]
[1153]
Maximumdiameter[m]
[1204] Linespdsource
[1284] Refspdsource
[1156] Linespeedgain
[1285] Refspeedgain
[1163] Baseomega[rpm]
[1155] Refspeedthr[%]
[1162] Diamlter[ms]
[1206] Diaminitlter[ms]
[1207]
Diamstdydelay[ms]
[1157] Diamreset
[1158] Diamthr[%]
[1159] Diamreached
[1168] Diampresetsel
[1164] Diampreset0[m]
[1165] Diampreset1[m]
[1166] Diampreset2[m]
[1167] Diampreset3[m]

Table of Contents