6.11.9 Address for bus operation
CONFIGURATION
Set serial comm
[319] Deviceaddress
[408] Seranswerdelay
[323] Serprotocolsel
[326] Serbaudratesel
ThecongurationmodesrelatingtotheserialcommunicationaredenedinthesubmenuSet serial comm.
Parameter description No.
Value
Standard
Conguration
min max
Factory
American
Factory
Standard
Device address
319 0 127 0 0
-
Ser answer delay
408 0 900 0 0
-
Ser protocol sel
SLINK3*(0)
MODBUSRTU(1)
JBUS(2)
323 0 2 SLINK3(0) SLINK3(0)
-
Ser baudrate sel
19200(0)
9600(1)
4800(2)
2400(3)
1200(4)
326 0 4 9600(1) 9600(1)
-
*ForSLINK3thebaudrateissteadyat9600.
note! ThesettingofSerprotocolselandSerbaudrateselbecomeactiveduringtheDrivestartup:
theymustthereforebestoredandthedrivehastobeswitchedoff.Seethespecicmanual
forthenumberingsystemoftheregistersandcoilsMODBUSRTUandJBUS.
Device address AddresswiththedrivecanbeaccessedifitisnetworkedviatheRS485interface.
(Forconnectionseesection4.5.“Serialinterface”).
Ser answer delay
Settingoftheminimumdelaybetweenthereceivingofthelastbytefromtheconverter
andthebeginningofitsanswer.Thisdelayavoidsconictsontheserialline,incasethe
interfaceRS485ofthemasterisnotarrangedforanautomaticcommunicationTx/Rx.
TheparameteronlyconcernstheworkingwithstandardseriallineRS485.
examPle: ifthedelayofthecommutationTx/Rxonthemasterisatitsmax.20ms,thesettingofthe
parameterSer answer delayshouldbeatahighernumeberof20ms:22ms.
Ser protocol sel Serialprotocolsignalingprocedure.
Ser baudrate sel Baudrateselection(exceptforSLINK3)