gefran TPD32-EV-...-4B - Figure 6.11.5.1: Speed Feedback

gefran TPD32-EV-...-4B
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
—————— Instruction manual ——————
189
Speed
Index Storing
Motor
A
H
Tacho
+
-
Tach generator
CEMF
Armature
Fbk Bypass
Encoder 1 Sinusoidal
6
5
1
8
4
3
A+
A-
B+
B-
C+
C-
0V
5V
XE1 connector
9
7
Encoder 1 Digital
6
5
1
8
4
3
A+
A-
B+
B-
C+
C-
0V
24
XE2 connector
2
7
Enable ind store
Disabled
Encoder 2 pulses
1024
Refresh enc 2
Disabled
Encoder 1 pulses
1024
Refresh enc 1
Disabled
Speed fbk sel
Armature
Speed fbk sel
Encoder 1
Speed fbk sel
Encoder 2
Speed fbk sel
Tacho
Enc 1 speed
PD output PID
Encoder 1 state
Encoder 2 state
Speed offset
0
Tacho scale
1
Actual spd (d)
Max. out voltage
500 V
Output voltage
Enable fbk bypass
Disabled
Figure 6.11.5.1: Speed feedback
Motor max speed Maxmotorspeed.Itisusedtoconverttachandarmaturefeedbackvaluesinrpm.Incase
ofspeedfeedbackfromtachogeneratoritisusedtoconvertthetachvoltageinanrpm
value.IncaseofarmaturevoltagefeedbackMax out voltageparameterisconsidered
equivalenttoMotor max speed.
Speed fbk sel Selectwhichfeedbackhastobeused.
Encoder1 ThesinusoidalencoderconnectedththeXE1connectorisused.
Encoder2 ThedigitalencoderconnectedtotheXE2connectorisused
(standard).
Tacho Theanalogtachogeneratorconnectedtotheterminals+and-isused.
Armature Theinternalmeasurementofthearmaturevoltageisused.No
externalconnectionisrequired.
Enable fbk contr Enableofthecontrolforthespeedfeedback.
Enabled Enabledcontrol
Disabled Disabledcontrol
Thisfunctioncontrolsthespeedfeedback,whereacomparisonbetweenthearmature
voltageandthespeedvaluereadbytheencoderorbythetachometerismade.Whenan
excursionhigherofthevaluesetviaSpeed fbk errorissignaled,thefailuremessage
“Speedfbkloss”appears.Thisfunctionisautomaticallydisabledwhenthearmature
feedbackhasbeenselected.(Speed fbk sel=Armature).
Enable fbk bypas Enableoftheautomaticchangeintoanarmaturefeedbackwhenthefailuremessage
“Speedfbkloss”iscausedbyalackoftheencoderortachometerfeedback.
Enabled Enabledautomaticchange
Disabled Disabledautomaticchange
Afteranautomaticchangeintoanarmaturefeedback,thespeedregulatorworkswiththe
Speed P bypassandSpeed I bypassparametersoftheREGPARAMETERS/Percent
values/Speedregulatormenu.Thefailuremessage“Speedfbkloss”withanenable
mustbeconguredsothatitissetas“Activity=Warning”.
Possibleworkingonlywithconstanteldcurrent.