Autotune CommandsautotuningofthePIcurrentregulator(seedescriptionofautotuningbelow)
Autotune Status IndicatestheautotuningstatusofthePIcurrentregulator.
Thevalue“Notexecuted”indicatesthatautotuninghasneverbeenrun(valueparameter
assumesatpoweron),thevalue“Inprogress”indicatesthatautotuningisrunning,the
value“Success”indicatesthatthelasttimeautotuningwasrunitendedsuccessfully.
Theothervaluesindicatethatthelasttimeautotuningwasrunitendedwithanerror
(forthetypeoferrorcorrespondingtothevariousvalues,seethedescriptionofthe
autotuningprocedurebelow).
T Current Ref
P Gain
DC Curr P
DC Curr P* CD Factor P
CD Curr Thr
T Current Ref
I Gain
DC Curr I
DC Curr I * CD Factor I
CD Curr Thr
A2.2 Regulator parameters (REG PARAMETERS)
Thissectionmodieschapter"6.10RegParameters"onpage180:
additionofDC Curr PI regmenu(aftertheSpeed regulatormenu),
additionofparameterstotheIn use values menu.
REG PARAMETERS
Percent values
Speed regulator
[...] ....
DC Curr PI reg
[847] DCCurrP
[848] DCCurrI
[849] DCCurrPbase
[850] DCCurrIbase
Flux regulator
[...] ...
Voltage reg
[...] ...
Base values
....
In use values
[...] ...
[845] CurrPinuse[%]
[846] CurrIinuse[%]
Parameter No. Format
Value Access via
min max Factory Keyp.
RS485/
BUS/
Opt2-M
Term.
Opt2-A/
PDC