Speed P bypass ProportionalgainK
P
*ofthespeedregulatorexpressedasapercentageofSpeed P
base,whenafeedbackviaencoderortachometerischangedintoaarmaturefeedback
(Enable fbk bypas=Enabled).
Speed I bypass IntegralgainK
I
*ofthespeedregulatorexpressedasapercentageofSpeedIbase,when
afeedbackviaencoderortachometerischangedintoaarmaturefeedback(Enablefbk
bypas=Enabled).
Fld reg P gain ProportionalgainK
P
*oftheeldcurrentregulatorexpressedaspercentageofFlux P
base.
Fld reg I gain IntegralgainK
I
*oftheeldcurrentregulatorexpressedasapercentageofFlux I
Base.
Voltage P ProportionalgainK
P
*oftheeldvoltageregulatorexpressedasapercentageofVolt-
age P base.
Voltage I IntegralgainK
I
*oftheeldvoltageregulatorexpressedasapercentageofVoltage I
base.
Speed P base ProportionalgainK
P0
ofthespeedregulatorinA/rpm(basevalue)
Speed I base IntegralgainK
I0
ofthespeedregulatorinA/rpm·ms(basevalue)
Flux P base ProportionalgainK
P0
oftheeldcurrentregulator(basevalue)
Flux I Base IntegralgainK
I0
oftheeldcurrentregulatorin(basevalue)
Voltage P base ProportionalgainK
P0
oftheeldvoltageregulatorinA/Vs(basevalue)
Voltage I base IntegralcoefcientK
I0
oftheeldvoltageregulatorinA/V·ms(basevalue)
Speed P in use Displayoftheactiveproportionalcoefcientofthespeedregulatorasapercentageof
Speed P base.
Speed I in use Displayoftheactivederivativecoefcientofthespeedregulatorasapercentageof
Speed I base.
Themaximumvaluefortheregulatorparametersisdenedbythebasevalues.Thesettingspossibledependon
thesizeofthedevice.
Theusercanoptimizethefunctionoftheregulatorbychangingthepercentagevalues(valuesmarkedwith*).
Theresultinggainsfortheregulatorarecalculatedasfollows:
K
P
=K
P0
·K
P
*/100% K
I
=K
I0
·K
I
*/100%
Exampleofthespeedregulator:
Speed P base=12(=K
P0
) Speed P=70%(=K
P
*)
ProportionalgainK
P
=12·70%/100%=8.4
Thebasevalues...basearealsothebasisforsettingtheadaptivespeedregulator.
Whentheadaptivespeedregulatorisenabled(Enable spd adap=Enabled),theSpeed PandSpeed Iparameters
havenoeffect.Theystillretaintheirvalueandareeffectiveagainwhenthespeedregulatoradaptionisdisabled.
TheSpeed P in useandSpeed I in use parametersindicatethecurrentgainsforthespeedregulator.Thisalso
applieswhenthespeedregulatoradaptionisactive.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran TPD32-EV-...-4B and is the answer not in the manual?

gefran TPD32-EV-...-4B Specifications

General IconGeneral
Brandgefran
ModelTPD32-EV-...-4B
CategoryDC Drives
LanguageEnglish

Related product manuals