—————— Instruction manual ——————
345
DIGITALINPUT3
Winder side Selectionofthewinding/unwindingside:incasetheselectioniscarriedoutviaadigital
input:0=UP,1=Down
DIGITALINPUT4
Diam reset Diameterreset.Whenthisparameterisenabled,thediametergetsthestartingvalue
selectedwithDiam preset sel.
If2-4differentvaluesofthestartingdiameterhavebeenset,theselectionhastobecarried
outviasomeprogrammeddigitalinputssuchas: Diam preset sel 0- Diam preset sel 0
Ifthevalueofthestartingdiameterissetviaananaloginput,setDiam preset sel=3.
Incaseofawindercontrol,itisnecessarytogivearesetcommandeverytimeacoil
changeisperformedbysettingtheminimumdiametervalue(winderemptydiam.)
Incaseofanunwindercontrol,itisnecessarytogivearesetcommandeverytimeacoil
changeisperformedbysettingthemaximumdiametervalue(windermaximumdiam.).
EnabletheparameterDiam resetforatimelongerthan20ms.
Resetthedigitalinputstatusbeforethestart
DIGITAL INPUT 5
Diam preset sel 0
DIGITAL INPUT 6
Diam preset sel 1 Incaseofasystemwithawinderorunwindercontrol,itispossibletosetinDiam preset
0thevalueofthestartingdiameter;forthewindercontrolaminimumdiameter,forthe
unwindercontrolamaximumdiameter.SetDiam preset sel =0(donotsetanydigital
inputasdiampresetsel0-diampreset1).BystartingthecommandofDiam resetthe
valueofdiampreset0isenteredinRoll diameter.
OPTIONMenu
————>Torquewinder
Torque winder En ;setEnable toenablethecenterwindfunction.
Ifthesystemrequiresit,itispossibletosetthisfunction(enable/disable)alsoviaa
digitalinput.
Setting of the parameters in the DIAMETER CALCULATION menu
PARAMETERS
OPTIONMenu
————>Torquewinder
————>Diamcalculation
Wind/unwind Winder/unwinderselection.Selectiontobecarriedoutonlyifthedigitalinputsarenotset.
Minimum diameter Minimumdiametervaluein[mm].Set100mm
Maximum diameter Maximumdiametervaluein[m].Set0.7m
Line spd source Numberofthesamplingparameterofthelinespeed.Inordertogettherealnumberto
besetitisnecessarytoadd+2000H(8192decimal)totheparameternumber.