304
PARAMETERS
June 1999
96-8000
Parameter 335 Z LS PER REV
This parameter is used on machines equipped with linear scales. This parameter should be set
to 50,000 on mills fitted with linear scales. On all other mills, they should be set to zero.
Parameter 336 A LS PER REV
This parameter is used on machines equipped with linear scales. This parameter should be set
to 0 on mills with or without linear scales.
Parameter 337 B LS PER REV
This parameter is used on machines equipped with linear scales. This parameter should be set
to 0 on mills with or without linear scales.
Parameter 339 X SPINDLE THERM COEF.
This parameter supports the Spindle Head Thermal Compensation feature, and should be set
to 0.
Parameter 340 Y SPINDLE THERM COEF.
See parameter 339 for description.
Parameter 341 Z SPINDLE THERM COEF.
See parameter 339 for description.
Parameter 342 A SPINDLE THERM COEF.
See parameter 339 for description.
Parameter 343 B SPINDLE THERM COEF.
See parameter 339 for description.
Parameter 345 X SPINDLE THERM T.C.
This parameter supports the Spindle Head Thermal Compensation feature, and should be set
to 0.
Parameter 346 Y SPINDLE THERM T.C.
See parameter 345 for description.
Parameter 347 Z SPINDLE THERM T.C.
See parameter 345 for description.
Parameter 348 A SPINDLE THERM T.C.
See parameter 345 for description.
Parameter 349 B SPINDLE THERM T.C.
See parameter 345 for description.