34
INSTALLATION
June 1999
96-8000
INITIAL SETUP
WARNING!
At this point, there should be NO electrical connection to the machine. The electrical panel should be closed
and the three latches on the door should be secured at all times except during installation and service. At
those times, only qualified electricians should have access to the panel. When the main switch is on, there is
high voltage throughout the electrical panel (including the circuit boards and logic circuits) and some compo-
nents operate at high temperatures. Therefore, you must exercise extreme caution when you are working in the
panel.
1. Set the main switch at the upper right of the electrical panel on the back of the machine to OFF.
2. Using a screwdriver, unlock the two latches on the panel door, unlock the cabinate with the key,
and open the door.
3. The manuals are located at the bottom left of the panel.
4. Take sufficient time to check all the components and connectors associated with the circuit
boards. With the power off, push on them gently to make sure that they are seated in their sock-
ets. Look for any cables that have become disconnected, look for any signs of damage and loose
parts in the bottom of the panel box. If there are any signs that the machine was mishandled, be
extremely careful in powering up the machine (be ready to shut it off IMMEDIATELY). Or if there
are obvious problems, call the factory BEFORE proceeding.