314
ALARMS
June 1999
96-8000
193 B Axis Drive Fault Same as alarm 161.
194 B Zero Ret Margin Too Small This alarm will occur if the home/limit switches move or are
misadjusted. This alarm indicates that the zero return position
may not be consistent from one zero return to the next. The
encoder Z channel signal must occur between 1/8 and 7/8
revolution of where the home switch releases. This will not turn
the servos off but will stop the zero return operation.
195 B Cable Fault Same as alarm 182.
196 Coolant Spigot Failure Vertical mills only. Spigot failed to achieve commanded location
after two (2) attempts.
197 100 Hours Unpaid Bill Call your dealer.
198 Precharge Failure During TSC operation, the precharge failed for greater than 0.1
seconds. It will shut off the feed, spindle and pump all at once. If
received, check all air lines and the air supply pressure.
199 Negative RPM A negative spindle RPM was sensed.
201 Parameter CRC Error Parameters lost maybe by low battery. Check for a low battery
and low battery alarm.
202 Setting CRC Error Settings lost maybe by low battery. Check for a low battery and
low battery alarm.
203 Lead Screw CRC Error Lead screw compensation tables lost maybe by low battery.
Check for low battery and low battery alarm.
204 Offset CRC Error Offsets lost maybe by low battery. Check for a low battery and low
battery alarm.
205 Programs CRC Error Users program lost maybe by low battery. Check for a low battery
and low battery alarm.
206 Internal Program Error Possible corrupted program. Save all programs to floppy disk,
delete all, then reload. Check for a low battery and low battery
alarm.
207 Queue Advance Error Software Error; Call your dealer.
208 Queue Allocation Error Software Error; Call your dealer.
209 Queue Cutter Comp Error Software Error; Call your dealer.
210 Insufficient Memory Not enough memory to store users program. Check the space
available in the LIST PROG mode and possibly delete some