5 June 2020 CasTemp Wireless including CasTemp Superheat Page 1
9.4.5 Telegram Output
The following table shows the output of a telegram in the 4 possible conditons: paired; non-paired; loss of transmission or open cicuit.
Telegram Input
Paired
Not - Paired
Loss of Transmission
Open Circuit
Character
Length
Output Value
Character
Length
Output Value
Character
Length
Output Value
Character
Length
Output Value
Superheat
6
0009.9
6
UUUU.U
6
LLLL.L
6
FFFF.F
Liquidus
6
1500.1
6
UUUU.U
6
LLLL.L
6
FFFF.F
Time of Liquidus
19
13/02/2018
11:45:24
19
CLEAR
19
CLEAR
19
CLEAR
Battery Charge
QUBE
4
098%
4
UUUU
4
LLLL
4
FFFF
Heat Number
8
ABCD1234
8
UUUUUUUU
8
LLLLLLLL
8
FFFFFFFF
Prediction
6
------
6
UUUUU.U
6
CLEAR
6
CLEAR
Ladle Empty
6
--------
6
CLEAR
6
CLEAR
6
CLEAR
SH Limit Time
19
-------------------
19
CLEAR
19
CLEAR
19
CLEAR
Rate of Change
6
002.34
6
UUU.UU
6
LLLL.L
6
FFFF.F

Table of Contents