EasyManuals Logo

HIKVISION DS-7608NXI-I2/8P/4S User Manual

HIKVISION DS-7608NXI-I2/8P/4S
161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #72 background imageLoading...
Page #72 background image
DS-76xx-I2/xP/4S NVR UM
72
Manually Rebuild Array
Purpose
If no hot spare disks are configured, rebuild the degraded array manually.
Before you start
At least one available physical disk should exist for rebuilding the array.
1) Go to Storage > RAID Setup > Array.
Figure 8-6 Array List
2) Click of the degraded array.
Figure 8-7 Rebuild Array
3) Select the available physical disk.
4) Click OK.
5) Click OK on the “Do not unplug the physical disk when it is under rebuilding pop up message
box.
Delete Array
Deleting array will delete all the data saved in it.
1) Go to Storage > RAID Setup > Array.