6-12
6.2.8 Makeup Replenishment Time-out
[CAUTION]
If you remove the solenoid valve or other piping part without relieving the
pressure from the path, the ink may gush out. Before performing the above
steps, be sure to provide pressure relief.
Makeup Replenishment
Time-out
Does the MV7 (Makeup valve)
oper
Does the MV7 operate when
the connector of the other
operating solenoid valve is
Replace MV7 or clean any ink
build up or other foreign
matters on MV7.
Is the connection harness
Replace the EZJ126 board.
Is the fault cleared by
power-on reset?
Disconnect the connectors, then
reconnect them (3 connectors).
CN13 of the EZJ126 board,
CN1 or CN3 of or EZJ132 board
The makeup does not flow into
the main ink tank from the
makeup reservoir when Pump
and MV7 are operated on the
solenoid valve/Pump test screen
Refer to 4.14 Trouble shooting
Procedure for the Circulation System,
Probable cause : The makeup pump
malfunctions, and Then, repair or replace
Makeup Pump.