EasyManua.ls Logo

Hitachi IJ UX - Page 241

Hitachi IJ UX
308 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-23
6.2.22 Viscometer Ink Temperature Sensor Fault
6.2.23 Ink Heating Unit Temperature Low
Ink
Heating Unit Temperature Low
Disconnect the EZJ125
board CN7 connector and
reconnect it.
Replace the heating unit.
Replace the EZJ125 board.
Is the fault issued
again?
Yes
No
Resume the
operation.
Is the fault issued
again?
Yes
No
Replace the EZJ126 board.
Is the fault issued
again?
Yes
No
Viscometer Ink
Temperature Sensor
Fault
Replace the thermistor of Viscometer.
Replace the EZJ126 board.
Resume the
operation.
Does the fault rec
ur?
Yes
No
Does the fault recur?
Yes
No
Disconnect and reconnect the following
connectors.
EZJ126: CN13
EZJ132: CN1, 3
Thermistor relay harness connector

Table of Contents

Other manuals for Hitachi IJ UX

Related product manuals