3 Press Automatic adjustment.
During automatic adjustment, “in progress” is displayed as the processing status.
The excitation voltage is automatically adjusted inside the IJ printer.
The excitation voltage is gradually increased, and the adjustment is completed
at 360 V ± 20V p-p. (Excitation adjustment is automatically completed within 90 seconds.)
4 When completed, the processing status is displayed to be “Ended”.
5 If automatic adjustment fails, the Manual adjustment key is displayed.
Main causes of automatic adjustment failure
Cause
1
The connection of the EZJ126 board and EZJ125 board is insufficient.
2
The dip switch on the EZJ125 board is incorrectly set.
3 The connection of the coaxial cable connector for excitation (EZJ125
CN5) is
insufficient.
4
Replacement parts are out of order (EZJ126/EZJ125 board, nozzle, head
cable).
Proc. status: In progress
Proc. status: Ended
Adjust./oper. checkout
<Excitation adjustment>
0752
Excitation voltage value
(0-2047)
Proc. status: Failed
[Stop ]
2015.07.07 12:45
Com=0
Back
Automatic
adjustment
Manual
adjustment
Manual adjustment

Table of Contents

Other manuals for Hitachi IJ UX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi IJ UX and is the answer not in the manual?

Hitachi IJ UX Specifications

General IconGeneral
BrandHitachi
ModelIJ UX
CategoryPrinter
LanguageEnglish

Related product manuals