Does the trouble fixed when the connetors 
below are disconnected once and reconnected? 
 
-CN20, CN23, CN2, CN34 and CN28 of EZJ133 
  -CN4 of EZJ113 
-CN4 of EZJ139 
  -CN2 of EZJ114 
  (*1):  When  you  replace  EZJ114  board, 
refer  to  [Notes  in  case  of  the  board 
replacement]  in  “3.3.11  EZJ114 
board (LED / SW board)”. 
(*2): When you replace EZJ113 board, refer 
to  [Replacement  procedures  of 
EZJ113  board]  in  “3.3.19  EZJ113 
board (Power relay board 1)”.
 
(*3): When you replace EZJ134 board, refer 
to  [Replacement  procedures  of 
EZJ134  board]  in  “3.3.6  EZJ134 
board (Nozzle2 drive board)”.
 
  (*4):  When  you  replace  Multiple  power 
supply1,  refer  to  [Replacement 
procedures of multiple power supply] 
in  3.3.15  Multiple  Power  Supply  1 
and 2.
 
  (*5):  When  you  replace  EZJ133  board, 
refer  to  [Replacement  procedures  of 
EZJ133  board]  in  “3.3.1  EZJ133 
board (MPU board)”. 
  [Caution] 
Be  sure  to  check  that  there  is  no  wrong 
connection  of  harnesses  by  referring  to 
[Connector  numbers  and  Identifying 
method  of  harnesses]  in  “3.3.20  Electrical 
Connection Diagram”.