6-101 
     6.5.18    No ink suction from gutter 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
*1) Recovery route operation check: 
This operation is the work for checking of the ink clogging in recovery route. 
[Operation procedures] 
(1) On “Solenoid v/p test” screen, press Pump1 “Operated” first, and then press “MV3” on <Nozzle1>. 
Secondly press Pump2 “Operated”, and then press “MV23” on <Nozzle2>.   
(2) Sprinkle makeup on the gutters, and check if the makeup is suctioned. 
No ink suction   
from gutter 
Execute the “Recovery route   
operation check”.    *1) 
Replace the recovery filter 1(or 2) 
Is the tube of recovery   
line or exhaust line folded? 
Or, is ink clogged? 
Does MV3 (nozzle1) and 
MV23 (nozzle2) operate? 
Clean the gutter and gutter   
base. 
Repair the ink fixing of 
  MV3 (nozzle1) and MV23 
(nozzle2) replace it. 
Replace the tube or clean 
the tube. 
Replace the recovery pump. 
Repair the ink fixing in recovery pump1(or 2). 
回収ポンプ1(または2)の固着修復を行う