2-45
2 Circulation sequence execution data (SEQUENCE.TXT)
[Circulation sequence execution data output]
(1) Output contents of Circulation sequence execution data
- Date : Date when the circulation sequence was executed
- Start time : Time when the circulation sequence started
- Finish time : Time when the circulation sequence completed
- Code : Code number of the Circulation sequence
- Sequence name : Name of the Circulation sequence
- Result : Processing result
Result 0 : Normally completed
Result 1 : Aborted and Skipped
(Note: Ink refill, etc. is saved as Aborted and Skipped due to detection of the
initial level of the main ink tank even it is normally completed.)
Result 2 : Aborted
Result 3 : Completed with failure
- Aborted step No.: Number of the step which was Aborted and Skipped
- Info1 : Operation status during special processing within the Circulation sequence
- Info2 : Operation status during special processing within the Circulation sequence
- Info3 : Operation status during special processing within the Circulation sequence
- Info4 : Operation status during special processing within the Circulation sequence
- Info5 : Operation status during special processing within the Circulation sequence

Table of Contents