2-49
Code
Sequence name
Date
Time
Information
003
Select message
2018/08/28
8:15:40
0001, OK
Record timing: When the message is selected (Manual only)
Logging contents: Selected message number and result (Normal or Fault)
Code
Sequence name
Date
Time
Information
004
Clear Fault/Warning log
2018/08/28
8:15:40
Record timing: When <Clear> key is pressed on Fault/Warning log screen
Code
Sequence name
Date
Time
Information
005
Set Viscosity
2018/08/28
8:15:40
0000, , 1993
Record timing: When Ink viscosity coefficient is changed on Unit information screen
Logging contents: Settings of Before change/After change of Ink viscosity coefficient
Code
Sequence name
Date
Time
Information
006
Excitation V-ref
2018/08/28
8:15:40
0019, , 0004
Record timing: When the Excitation V-ref is changed on Excitation V update screen
Logging contents: Settings of Before change/After change of Excitation V-ref.
Code
Sequence name
Date
Time
Information
007
Serial number change
2018/08/28
8:15:40
00000000, ,00000532
Record timing: When the Serial number is changed
Logging contents: Settings of Before change/After change of the Serial number
Code
Sequence name
Date
Time
Information
008
Unmatched model key
2018/08/28
8:15:40
[EZJ128],0013141105600D8B0
000000010000000
[found],2018/01/28,00:00:00,
[model],5A13141105600D8B000
0000000000000
Record timing: When the model key was detected as unmatched
Logging contents: Information of [EZJ128] board, date and time when Unmatched was first
[found], and information of [model] (language key board)
Code
Sequence name
Date
Time
Information
009
CM clock
[CCPU],2018/08/24,23:49:52,
[TCPU],2018/08/24,23:49:53
Record timing: When the power is turned on and the start-up process is activated
Logging Contents: Time [CCPU] and [TCPU] were activated
Code
Sequence name
Date
Time
Information
010
Restore
2018/08/28
8:15:40
00000532,07,OK
Record timing: When Restore (Data copy) was executed
Logging contents: Information of the printer serial number of copy destination, Data copy mode, and
the result (Normal/Cause of abnormality)
[Data copy mode]
01: Copy user pattern
02: Copy standard characters
04: Copy print data
08: Copy unit-specific data
[Example] Data copy mode of 07
07 (=01+02+04) means that the user pattern, the standard characters and the print data
were selected as the copy targets.

Table of Contents

Other manuals for Hitachi UX Twin Nozzle

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi UX Twin Nozzle and is the answer not in the manual?

Hitachi UX Twin Nozzle Specifications

General IconGeneral
BrandHitachi
ModelUX Twin Nozzle
CategoryPrinter
LanguageEnglish

Related product manuals