2-51
Code
Sequence name
Date
Time
Information
013
Upgrade-key is short
2018/01/28
8:15:40
[found],2018/01/28,13:00:00,
[key],01, [step],07
Record timing: When it is judged as Upgrade key is short.
Logging contents: 1. The date and time when the discrepancy was first [found]
2. [key] The number of upgrade keys which are inserted at present
3. [step] The number of steps required for the upgrade setup
(For management purpose, the number of steps +5 is recorded.)
Example: [step] 7 means 2 steps were set on the upgrade setup screen.
Code
Sequence name
Date
Time
Information
015
Ambient temp. upper lim.
2018/08/28
8:15:40
35, , 40
Record timing: When Ambient temperature upper limit is changed on System Environment setup
screen
Logging contents: Settings of Before change/After change of Ambient temperature limit value
Code
Sequence name
Date
Time
Information
016
Excitation V-ref. (Max)
2018/08/28
8:15:40
19, , 27
Record timing: When Excitation V-ref. (Max) is changed on System Environment setup screen
Logging contents: Settings of Before change/After change of Excitation V-ref. (Max)
Code
Sequence name
Date
Time
Information
017
Unmatched language
key
2018/08/28
8:15:40
[found],2018/08/28,00:00:00,
[EZJ128],00000000,
[EZJ121B],2147483647,J
Record timing: When Unmatched language key is detected
Logging contents: 1. [found] Initial occurrence date of mismatch
2. Serial numbers of [EZJ128] and [EZJ121B] (Board of Language key)
3. [J] Japanese can be set, [W] Japanese can NOT be set
Code
Sequence name
Date
Time
Information
018
Time of preparing for
print
2018/08/28
8:15:40
[found], 2018/08/28,13:00:00,
[key],01,[step],07
Record timing: When Upgrade recovery is detected
Logging contents: 1. [found] Initial occurrence date of mismatch
2. [key] The number of upgrade keys installed at the moment
3. [step] The number of steps required for the upgrade setup.
(For management purpose, value of number of steps +5 is recorded.)
Example: [step] 7 means 2 steps were set on the upgrade setup screen.
Code
Sequence name
Date
Time
Information
019
Time of preparing for
printing
2018/08/28
8:15:40
Short, , Standard
Record timing: When Time of preparing for printing was changed on the second screen of Print
specification screen
Logging contents: Settings of Before change/After change of [Time of preparing for printing]
Code
Sequence name
Date
Time
Information
021
Ink Drop Charge Rule
2018/08/28
8:15:40
Standard
(Single scan/Interlaced)
Mixed Single scan and
Interlaced
Record timing: When setting of Ink Drop Charge Rule was changed on the third screen of Print
specification screen
Logging contents: Settings of Before change/After change of [Ink Drop Charge Rule]
Code
Sequence name
Date
Time
Information
023
Print Overlap Fault
Check
2018/08/28
8:15:40
Disable, , Enable
Record timing: When setting of Print Overlap Fault Check was changed on User environment setup
screen

Table of Contents

Other manuals for Hitachi UX Twin Nozzle

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi UX Twin Nozzle and is the answer not in the manual?

Hitachi UX Twin Nozzle Specifications

General IconGeneral
BrandHitachi
ModelUX Twin Nozzle
CategoryPrinter
LanguageEnglish

Related product manuals