3-6 
(11) Confirm “Serial number” on the “Unit information” screen and then confirm the 
 date and time. 
(12) Recover the data from the back up memory by using "Copy data (USB→IJP)" 
  function. 
  (Data is from USB memory to IJ printer) 
 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
(Note. 1) "Print data" means the data of print description, print specification, the print line, 
          print format, calendar and count. 
(Note. 2) Unit-data means ink type, nozzle diameter and viscosity calibration data. 
 
-  When  the  EZJ128  board  is  replaced  with  having  NO  backup  available,  follow  the 
procedures below. 
 
[Replacement procedures of EZJ128 board with NO back up is available] 
(1) Turn off the power. 
(2) Open the control panel and remove connection cable and battery on the EZJ128 
 board. 
(3) Replace the EZJ128 board. 
(4) Attach the connection cable and battery to the EZJ128 board. 
(5) Turn on the power with system data USB memory inserted.   
(6) Execute “System reset” on the second page of the service maintenance screen. 
(7) Confirm “Serial number” on the “Unit information” screen and then confirm the 
 date and time. 
(8) Set or adjust the data according to the following table. 
 
Calibrate touch screen 
coordinates 
Instruction manual 
“7.4 Calibrating the Touch Screen coordinates” 
Instruction manual “6.3 Touch screen setup” 
“2.2 System environment setup” 
“2.2 System environment setup” 
“2.3.1 Excitation adjustment” 
Viscometer calibration or   
Viscosity coefficient input 
“2.6.1  Calibration  of  viscometer”  or  input  ink  viscosity 
coefficient on “2.10 Unit information” 
Adjustment of auto phase   
gain value 
“2.3.4 Auto phase gain adjustment” 
Excitation voltage setting 
Technical manual “6.10 Excitation V Adjustment” 
Readjustment of auto phase 
gain value 
“2.3.4 Auto phase gain adjustment” 
Instruction manual “4.Creation and printing of message” 
Setting of substitution rules 
Instruction manual 
“4.10.3 Print by substituting  a  different character for  the 
date (Substitution rule)” 
Instruction manual “7.3 Creating a user pattern” 
Instruction manual “6.1 Setting the user environment” 
Setting the Date and Time   
Instruction manual “6.2 Setting a Date and Time” 
Setting Communication 
environment   
Technical manual “5 Communication” 
Technical  manual  “3.2  Setting  functions  which  can  be 
performed” 
For backup data function, the data type to be saved is different between the service 
personnel maintenance mode and user maintenance mode. When replacing the EZJ128 
board, change the mode to the service personnel maintenance mode and then perform 
the backup. 
  -User mode: User data (print data (Note 1), substitution rules, user patterns) 
  -Service personnel maintenance mode:   
User data (same as above) and unit-specific data (Note 2). 
After replacing the EZJ128 board, turn ON the power of the IJ printer and confirm the 
date and time. If the date and time displayed is not correct, adjust the setting again. 
As for the Unit   
Information, see “2.10 
Unit information”. 
As for the System 
reset, see “2.8 System 
reset”.