E1 Series Servo Drive User Manual Parameters
15-8 HIWIN MIKROSYSTEM CORP.
Size 2
0000~1001 Default 0000
Name
Application function
selection 8
Unit -
Rotary
Description
t.X
Alarm/warning selection for battery undervoltage Reference
0 Output alarm AL.810 when battery voltage is low. -
1 Output warning AL.930 when battery voltage is low. -
t.X Reserved (Do not modify.)
t.X Reserved (Do not modify.)
t.X
Thermal sensor detection Reference
0 Disable thermal sensor detection. -
1 Enable thermal sensor detection. -
Size 2
0000~1101 Default 0000
Name
Application function
selection 9
Unit -
All
Description
t.X
Axis selection of error map function Effective
0 Enable error map function for single axis.
After power
on
1 Enable error map function for gantry axes.
t.X Reserved (Do not modify.)
t.X
Velocity detection method selection Effective
Use velocity detection 1.
After power
on
1 Use velocity detection 2.
t.X
Error map function Effective
Disable error map function.
Immediately
1 Enable error map function.