E1 Series Servo Drive User Manual Parameters
15-10 HIWIN MIKROSYSTEM CORP.
MD09UE01-1910
Pt No.
Pt00B
Size 2
Setting
Range
0000~0121 Default 0000
Name
Application function
selection B
Unit -
Applicable
Motor
All
Effective
After power on
Category
Setup
Reference
-
Description
t.X
Parameter display on panel Reference
0 Display setup parameters only. -
1 Display all parameters. -
t.X
Stopping method for Gr.B alarm Reference
0 Zero velocity stop (Velocity command is set to 0 to stop the motor.) -
1
Use dynamic brake to stop the motor or let the motor run freely until it stops.
The stopping method is the same as Pt001 = t.X.
-
2 Use the stopping method set in Pt00A = t.X. -
t.X
Three-phase/single-phase power input selection Reference
0 Use three-phase AC power input. -
1 Use single-phase AC power input or three-phase AC power input. -
t.X Reserved (Do not modify.)
Pt No.
Pt00D
Size 2
Setting
Range
0000~1012 Default 1002
Name
Application function
selection D
Unit -
Applicable
Motor
All
Effective
After power on
Category
Setup
Reference
-
Description
t.X
Group communication axis selection Reference
0 Slave axis in group communication -
1 Master axis in group communication -
2 No gantry control -
t.X
Field-weakening control Reference
0 Disable field-weakening control. -
1 Enable field-weakening control. -
t.X
Auto switching for gantry control Reference
0 Disable auto switching for gantry control -
1 Enable auto switching for gantry control -
t.X
Overtravel warning detection selection Reference
0
Do not detect overtravel warnings.
-
1 Detect overtravel warnings. -

Table of Contents