EasyManua.ls Logo

Hiwin E1 Series

Hiwin E1 Series
394 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E1 Series Servo Drive User Manual Parameters
HIWIN MIKROSYSTEM CORP. 15-19
MD09UE01-1910
Pt No.
Pt20D
Size 2
Setting
Range
1~65535 Default 1
Name
Gear ratio at load
side (full-closed
loop)
Unit 1
Applicable
Motor
Rotary
Effective
After power on
Category
Setup
Reference
-
Pt No.
Pt20E
Size 4
Setting
Range
1~1073741824 Default 32
Name
Electronic gear ratio
(numerator)
Unit 1
Applicable
Motor
All
Effective
After power on
Category
Setup
Reference
-
Pt No.
Pt210
Size 4
Setting
Range
1~1073741824 Default 1
Name
Electronic gear ratio
(denominator)
Unit 1
Applicable
Motor
All
Effective
After power on
Category
Setup
Reference
-
Pt No.
Pt212
Size 4
Setting
Range
64~1073741824 Default 8192
Name
Number of encoder
output pulses
Unit 1 pulse edge
Applicable
Motor
Rotary
Effective
After power on
Category
Setup
Reference
-
Pt No.
Pt216
Size 2
Setting
Range
0~16384 Default 0
Name
Position command
acceleration/
deceleration time
constant
Unit 0.25 ms
Applicable
Motor
All
Effective
After motor stops
Category
Setup
Reference
-
Pt No.
Pt217
Size 2
Setting
Range
0~1000 Default 0
Name
Average position
command
movement time
Unit 0.25 ms
Applicable
Motor
All
Effective
After motor stops
Category
Setup
Reference
-

Table of Contents