EasyManuals Logo

Hiwin E1 Series User Manual

Hiwin E1 Series
394 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #351 background imageLoading...
Page #351 background image
E1 Series Servo Drive User Manual Parameters
HIWIN MIKROSYSTEM CORP. 15-19
MD09UE01-1910
Pt No.
Pt20D
Size 2
Setting
Range
1~65535 Default 1
Name
Gear ratio at load
side (full-closed
loop)
Unit 1
Applicable
Motor
Rotary
Effective
After power on
Category
Setup
Reference
-
Pt No.
Pt20E
Size 4
Setting
Range
1~1073741824 Default 32
Name
Electronic gear ratio
(numerator)
Unit 1
Applicable
Motor
All
Effective
After power on
Category
Setup
Reference
-
Pt No.
Pt210
Size 4
Setting
Range
1~1073741824 Default 1
Name
Electronic gear ratio
(denominator)
Unit 1
Applicable
Motor
All
Effective
After power on
Category
Setup
Reference
-
Pt No.
Pt212
Size 4
Setting
Range
64~1073741824 Default 8192
Name
Number of encoder
output pulses
Unit 1 pulse edge
Applicable
Motor
Rotary
Effective
After power on
Category
Setup
Reference
-
Pt No.
Pt216
Size 2
Setting
Range
0~16384 Default 0
Name
Position command
acceleration/
deceleration time
constant
Unit 0.25 ms
Applicable
Motor
All
Effective
After motor stops
Category
Setup
Reference
-
Pt No.
Pt217
Size 2
Setting
Range
0~1000 Default 0
Name
Average position
command
movement time
Unit 0.25 ms
Applicable
Motor
All
Effective
After motor stops
Category
Setup
Reference
-

Table of Contents

Other manuals for Hiwin E1 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hiwin E1 Series and is the answer not in the manual?

Hiwin E1 Series Specifications

General IconGeneral
BrandHiwin
ModelE1 Series
CategoryServo Drives
LanguageEnglish

Related product manuals