E1 Series Servo Drive User Manual Parameters
15-34 HIWIN MIKROSYSTEM CORP.
MD09UE01-1910
Pt No.
Pt50B
Size 2
Setting
Range
0000~BBBB Default B654
Name
Input signal selection
2
Unit -
Applicable
Motor
All
Effective
After power on
Category
Setup
Reference
-
Description
t.X
Allocation of alarm reset input (ALM-RST) signal Reference
0~B The allocation is the same as the one of servo on input (S-ON) signal. -
t.X
Allocation of forward external torque limit input (P-CL) signal Reference
0~B The allocation is the same as the one of servo on input (S-ON) signal. -
t.X
Allocation of reverse external torque limit input (N-CL) signal Reference
0~B The allocation is the same as the one of servo on input (S-ON) signal. -
t.X
Allocation of control method switching input (C-SEL) signal Reference
0~B The allocation is the same as the one of servo on input (S-ON) signal. -