E1 Series Servo Drive User Manual Parameters
15-34 HIWIN MIKROSYSTEM CORP.
Size 2
0000~BBBB Default B654
Name
Unit -
All
Description
t.X
Allocation of alarm reset input (ALM-RST) signal Reference
0~B The allocation is the same as the one of servo on input (S-ON) signal. -
t.X
Allocation of forward external torque limit input (P-CL) signal Reference
0~B The allocation is the same as the one of servo on input (S-ON) signal. -
t.X
Allocation of reverse external torque limit input (N-CL) signal Reference
0~B The allocation is the same as the one of servo on input (S-ON) signal. -
t.X
Allocation of control method switching input (C-SEL) signal Reference
0~B The allocation is the same as the one of servo on input (S-ON) signal. -