COOLING SYSTEM
6-9
Remove the bolts and thermostat housing cover.
Remove the thermostat from the housing.
INSPECTION
Wear insulated gloves and adequate eye protection.
Keep flammable materials away from the electric
heating element.
Visually inspect the thermostat for damage.
Check for damage of seal ring.
Do not let the
thermostat or
thermometer touch
the pan, or you will
get false reading.
Heat the water with an electric heating element to
operating temperature for 5 minutes.
Suspend the thermostat in heated water to check its
operation.
Replace the thermostat if the valve stays open at
room temperature, or if it responds at temperatures
other than those specified.
HOUSING COVER
SCREW
THERMOSTAT
THERMOSTAT HOUSING
THERMOSTAT OPERATING TEMPERATURE
(BEGIN TO OPEN):
80 – 84 °C(176– 183 °F)
VALVE LIFT:
8mm(0.3in)minimumat95°C (203 °F)