COOLING SYSTEM
6-10
INSTALLATION
Align the direction of the thermostat stamp mark
with the boss of housing.
Install the thermostat into the housing by aligning
the body with the groove of the housing.
Install the thermostat housing cover to the housing
by aligning the bosses of housing and cover.
Tighten the bolts to the specified torque.
Install a new O-ring to the thermostat housing
groove.
Install the thermostat housing to the cylinder head
and tighten the bolts securely.
Connect the bypass hose to the thermostat housing
and tighten the hose band screw securely.
Connect the ETC sensor 3P (Black) connector.
THERMOSTAT
BOSS
Align
STAMP
MARK
TORQUE: 12 N·m(1.2kgf·m, 9 lbf·ft)
HOUSING COVER
BOLTS
Align
O-RING
THERMOSTAT HOUSING
3P (Black)
CONNECTOR
BOLTS
SCREW
BYPASS
HOSE
THERMOSTAT HOUSING
O-RING