C-4
Error
Messages
Error
DA
SA
Code
Definition
Printer
6 0
OOOXXOO
Problem indicated by status byte
XX
defined below.
6
0
OOOOVYOI
Timed out while waiting for printer to complete self test
6 0 0000VY02 Flag did not go false after reading
FRO
6 0
0000VY03
Timed out while waiting for
flag
6
0 0000VY04 Failed loopback test
6 0
0000VY05
Printer not responding to poll
6
0
0000VY06
Printer failed self test
6
0 0000VY07 Printer responds to polls when disabled
6
0 0000VY08 Printer status false
6
0 0000VY09 Printer enabled for poll response after reset
6
0
OOOOVYOA
Keyboard PFW interrupt cannot be cleared
XX
= Printer status byte
in
following format:
PSFL DSTF MSTF
OOPP
HDFL VHLO PTTH HDTH
where:
PSFL = Power supply failure; motor drive board
bad
DSTF = Dangerous self test failure; potential damage to printhead
MSTF
= Minor self test failure; no potential damage to equipment
OOPP
=
Out
of
paper
HDFL = Printhead control line failure; BURN and/or CLEAR line stuck high or low
VHLO = Printhead supply voltage too low
PTTH = Power transistor
on
motor drive board too hot
HDTH
= Printhead too hot; temperature
in
printhead exceeded 70°C
VY
= Irrelevant
Error
DA
SA
Code
Definition
Keyboard
6 2
00000001
Failed loopback to FR15
6
2
00000002
Keyboard not responding to poll
6 2
00000003
Keyboard failed self test
6
2
00000004
Battery low condition detected
6
2
00000005
Keyboard not responding with
SRQ
bit
6
2
00000006
Keyboard not forcing status false
6
2
00000007
Reading FRIO did not clear keyboard poll response
6 2
00000008
Power
fail
warning bit set