disable-timer
loop-protect disable-timer < 0 to 604800 >
Set time in seconds to wait before attempting to reenable a port.
Range: < 0 to 604800 >
loop-detected
[no] loop-protect trap loop-detected
generate trap when a loop is detected
port-list
[no] loop-protect [ETHERNET] PORT-LIST
Specify the ports that are to be added to/removed from loop protection.
Next Available Option:
receiver-action < send-disable | no-disable > -- Select action to take when loop protect packets
are received on the specified port(s). (p. 371)
receiver-action
loop-protect [ETHERNET] PORT-LIST receiver-action < send-disable | no-disable >
Select action to take when loop protect packets are received on the specied port(s).
Supported Values:
send-disable
no-disable
transmit-interval
loop-protect transmit-interval < 1 to 10 >
Set time between packet transmissions.
Range: < 1 to 10 >
trap
[no] loop-protect trap
Specify loop protection traps that are to be enabled/disabled.
Next Available Option:
loop-detected -- generate trap when a loop is detected(p. 371)