EasyManuals Logo

HP ProCurve 5400zl User Manual

HP ProCurve 5400zl
765 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #619 background imageLoading...
Page #619 background image
Disables SNMP support for the hpSwitchAuthentication MIB.
extended
â–  [no] snmp-server enable traps snmp-authentication extended
Send traps for Extended Authentication failures.
host
â–  [no] snmp-server host
Usage: [no] snmp-server host IP-ADDR COMMUNITY-STR
[none|debug|all|not-info|critical]
[informs [retries RETRY-COUNT] [timeout TIMEOUT]]
Description: Dene SNMP traps and their receivers.
This command congures which network management stations
will receive SNMP event log messages from the switch and
the types of events for which the switch will send these
messages. In all cases, the switch will send all messages
resulting from thresholds, to the network management
station that explicitly set each threshold. The levels
specied on this screen correspond only to the traps set
for event log messages, not to those set for thresholds.
You can specify up to 10 trap receivers (network management
stations).
Parameters:
o COMMUNITY-STR - SNMP community string.
o IP-ADDR - IP address of SNMP notication host.
o [none|all|not-info|critical|debug] - The level of Switch
events that will generate a trap to be sent: none - send no log
message; all - send all log messages; not-info - send each log
message that is not informational-only; critical - send
critical-level log messages; debug (reserved for Internal use).
o [informs [retries RETRY-COUNT] [timeout TIMEOUT]] If 'informs'
is added to the command, informs rather than traps are sent.
Retries denes the number of retries to attempt when a response
is not received. The default is 3. Timeout denes the interval
between retries, measured in seconds. The default is 15 seconds.
Next Available Options:
â–  address -- IP address of SNMP notification host. (IP-ADDR) (p. 614)
â–  address_ipv6 -- IPv6 address of SNMP notification host. (IPV6-ADDR) (p. 615)
hpSwitchAuthMIB
â–  snmp-server mib hpSwitchAuthMIB
Usage: snmp-server mib hpSwitchAuthMIB <excluded|included>
617© 2009 Hewlett-Packard Development Company, L.P.
snmp-serverCommand Line Interface Reference Guide

Table of Contents

Other manuals for HP ProCurve 5400zl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 5400zl and is the answer not in the manual?

HP ProCurve 5400zl Specifications

General IconGeneral
BrandHP
ModelProCurve 5400zl
CategorySwitch
LanguageEnglish

Related product manuals